Drh300 Insulation Material Heat Flow Meter for Thermal Conductivity Measurement Test Equipment

Product Details
Customization: Available
After-sales Service: 1 Year
Warranty: 1 Year
Manufacturer/Factory & Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 3 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (22)
  • Drh300 Insulation Material Heat Flow Meter for Thermal Conductivity Measurement Test Equipment
  • Drh300 Insulation Material Heat Flow Meter for Thermal Conductivity Measurement Test Equipment
  • Drh300 Insulation Material Heat Flow Meter for Thermal Conductivity Measurement Test Equipment
  • Drh300 Insulation Material Heat Flow Meter for Thermal Conductivity Measurement Test Equipment
  • Drh300 Insulation Material Heat Flow Meter for Thermal Conductivity Measurement Test Equipment
  • Drh300 Insulation Material Heat Flow Meter for Thermal Conductivity Measurement Test Equipment
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Assembly and commissioning
  • Our services
  • Company Profile
Overview

Basic Info.

Model NO.
DRH300
Max Sample Size
300*300*100mm
Standards
ISO8301, ASTM C518, DIN En 12667
Transport Package
Standard Exporting Wooden Case
Specification
1CBM
Trademark
Hunan Zhenhua
Origin
China
HS Code
9031809090
Production Capacity
100sets/Year

Product Description

Product Description

DRH300 Series Precision heat flow meter for thermal conductivity measurement

Heat flow method is the world recognized insulation standard test method, thermal heat conduction device use double heat flux sensor, excellent temperature stability, heat conduction coefficient 0.005...0.5 W/(m * K), used in building materials, filling materials, powder materials, gypsum board, fibreboard and rubber and other fields. DRH300 is protect heat plate thermal conductivity apparatus, coefficient of thermal conductivity range 0.007...2.0 W/(m * K), its application field is similar to the heat flow method, is characterized by wide temperature range. Protect heat thermal conductivity meter is suitable for measuring the medium coefficient of thermal conductivity of solid materials, thermal conductivity range 0.1...10 w/(m * K), fast measuring speed, wide measuring range, used in plastics, rubber, sealing materials, ceramic, molten metal and circuit board materials and other fields.
Main features:
DRH300 series thermal conductivity meter is based on the steady-state method, is able to measure 30 cm x 30 cm samples, thickness ranging from a few millimeters to 10 (20)cm. All testing functions automatically; Motor control of the plate movement; Measurement set up and run very fast; Sample sandwiched between two heat flux sensor test, fixed or adjustable temperature gradient. In a few minutes after stability of temperature and temperature gradient, using the embedded controller or external computer measured the thermal conductivity and thermal resistance of the sample. Automatic upper plate move and sample thickness measurement, simplifies the test preparation. All test parameters and the correction data can be stored in the computer. Suitable for industrial applications, superior performance. DRH300 coefficient of thermal conductivity measurements conform to ASTM C 518, ISO 8301, JIS b 1412, DIN EN 12939, DIN EN 13163 with DIN EN 12667 and relevant international standards.
 
Product Parameters

Technical parameters:

        Model
Specifications
DRH300A DRH300B DRH300C
Average temperature range 0 ~40 ºC variable RT ~ 100 ºC variable -20 ~ 70 ºC variable
Cooling system external water bath external water bath forced air cooling
plate temperature control system Peltier system Peltier system Peltier system
programmable data points 10 10 10
Sample size(mm) 300×300×(10-100) 300×300×(10-100) 300×300×(10-100 )
Thermal resistance range 0.1 ~ 8.0 m2K/W
Coefficient of thermal conductivity range 0.005~ 2.0 W/m K
Repeatability 1% 1% 1%
Accuracy + / - 1% ~ 3%
Shape dimension reference 79×63×77 cm 94×72×88 cm 79×63×77 cm

Detailed Photos

 


Drh300 Insulation Material Heat Flow Meter for Thermal Conductivity Measurement Test Equipment

Drh300 Insulation Material Heat Flow Meter for Thermal Conductivity Measurement Test EquipmentDrh300 Insulation Material Heat Flow Meter for Thermal Conductivity Measurement Test Equipment
Assembly and commissioning
Drh300 Insulation Material Heat Flow Meter for Thermal Conductivity Measurement Test Equipment
Drh300 Insulation Material Heat Flow Meter for Thermal Conductivity Measurement Test Equipment
Drh300 Insulation Material Heat Flow Meter for Thermal Conductivity Measurement Test Equipment

 

Drh300 Insulation Material Heat Flow Meter for Thermal Conductivity Measurement Test Equipment
 
Our services
Drh300 Insulation Material Heat Flow Meter for Thermal Conductivity Measurement Test Equipment
 
Company Profile

Drh300 Insulation Material Heat Flow Meter for Thermal Conductivity Measurement Test Equipment
Drh300 Insulation Material Heat Flow Meter for Thermal Conductivity Measurement Test Equipment

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier